High-sensitivity Gd<sup>3+</sup>–Gd<sup>3+</sup> EPR distance measurements that eliminate artefacts seen at short distances
-
Published:2020-12-09
Issue:2
Volume:1
Page:301-313
-
ISSN:2699-0016
-
Container-title:Magnetic Resonance
-
language:en
-
Short-container-title:Magn. Reson.
Author:
EL Mkami HassaneORCID, Hunter Robert I.ORCID, Cruickshank Paul A. S., Taylor Michael J., Lovett Janet E.ORCID, Feintuch Akiva, Qi Mian, Godt Adelheid, Smith Graham M.
Abstract
Abstract. Gadolinium complexes are attracting increasing attention
as spin labels for EPR dipolar distance measurements in biomolecules and
particularly for in-cell measurements. It has been shown that flip-flop
transitions within the central transition of the high-spin Gd3+ ion
can introduce artefacts in dipolar distance measurements, particularly when
measuring distances less than 3 nm. Previous work has shown some reduction
of these artefacts through increasing the frequency separation between the
two frequencies required for the double electron–electron resonance (DEER)
experiment. Here we use a high-power (1 kW), wideband, non-resonant system
operating at 94 GHz to evaluate DEER measurement protocols using two stiff
Gd(III) rulers, consisting of two bis-Gd3+–PyMTA complexes, with
separations of 2.1 nm and 6.0 nm, respectively. We show that by avoiding
the -12→12 central transition completely, and placing
both the pump and the observer pulses on either side of the central
transition, we can now observe apparently artefact-free spectra and narrow
distance distributions, even for a Gd–Gd distance of 2.1 nm. Importantly we
still maintain excellent signal-to-noise ratio and relatively high
modulation depths. These results have implications for in-cell EPR
measurements at naturally occurring biomolecule concentrations.
Funder
Wellcome Trust Royal Society
Publisher
Copernicus GmbH
Reference37 articles.
1. Bahrenberg, T., Rosenski, Y., Carmieli, R., Zibzener, K., Qi, M., Frydman,
V., Godt, A., Goldfarb, D., and Feintuch, A.: Improved sensitivity for
W-band Gd(III)-Gd(III) and nitroxide-nitroxide DEER measurements with shaped
pulses, J. Magn. Reson., 283, 1–13, https://doi.org/10.1016/j.jmr.2017.08.003, 2017. 2. Clayton, J. A., Keller, K., Qi, M., Wegner, J., Koch, V., Hintz, H., Godt,
A., Han, S., Jeschke, G., Sherwin, M. S., and Yulikov, M.: Quantitative
analysis of zero-field splitting parameter distributions in Gd(iii)
complexes, Phys. Chem. Chem. Phys., 20, 10470–10492, https://doi.org/10.1039/C7CP08507A, 2018. 3. Cohen, M. R., Frydman, V., Milko, P., Iron, M. A., Abdelkader, E. H., Lee,
M. D., Swarbrick, J. D., Raitsimring, A., Otting, G., Graham, B., Feintuch,
A., and Goldfarb, D.: Overcoming artificial broadening in Gd3+-Gd3+
distance distributions arising from dipolar pseudo-secular terms in DEER
experiments, Phys. Chem. Chem. Phys., 18, 12847–12859, https://doi.org/10.1039/c6cp00829a, 2016. 4. Collauto, A., Frydman, V., Lee, M. D., Abdelkader, E. H., Feintuch, A.,
Swarbrick, J. D., Graham, B., Otting, G., and Goldfarb, D.: RIDME distance
measurements using Gd(iii) tags with a narrow central transition, Phys. Chem.
Chem. Phys., 18, 19037–19049, https://doi.org/10.1039/c6cp03299k,
2016. 5. Cruickshank, P. A., Bolton, D. R., Robertson, D. A., Hunter, R. I., Wylde,
R. J., and Smith, G. M.: A kilowatt pulsed 94GHz electron paramagnetic
resonance spectrometer with high concentration sensitivity, high
instantaneous bandwidth, and low dead time, Rev. Sci. Instrum., 80, 103102,
https://doi.org/10.1063/1.3239402, 2009.
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|