Author:
Oertel Stefan,Eggert Michael,Gutsmuths Christian,Wilhelm Paul,Müller Harald,Többen Helmut
Abstract
Abstract. Conventional monostatic wind lidar (light detection
and ranging) systems are well-established wind speed
remote sensing devices in the field of wind energy that provide reliable
measurement results for flat terrain and homogeneous wind fields. These
conventional wind lidar systems use a common transmitting and receiving unit
and become unacceptably inaccurate as the wind fields become increasingly
inhomogeneous due to their spatial and temporal averaging procedure (large
measurement volume) that is inherent to the monostatic measurement principle.
The new three-component fiber laser-based wind lidar sensor developed by the
Physikalisch-Technische Bundesanstalt (PTB) uses one transmitting unit (fiber
laser) and three receiving units to measure the velocity vector of single
aerosols in a spatially highly resolved measurement volume (with diameter
d and length l) in heights from 5 m (d=300 µm, l=2 mm) to 250 m (d=14 mm, l=4 m) with a resolution of about 0.1 m s−1.
Detailed comparison measurements
with a 135 m high wind met mast and a conventional lidar system have
proven that the high spatial and temporal resolution of the new, so-called
bistatic lidar leads to a reduced measurement uncertainty compared to
conventional lidar systems. Furthermore, the comparison demonstrates that the
deviation between the bistatic lidar and the wind met mast lies well within
the measurement uncertainty of the cup anemometers of the wind met mast for
both homogeneous and inhomogeneous wind fields. At PTB, the aim is to use the
bistatic wind lidar as a traceable reference standard to calibrate other
remote sensing devices, necessitating an in-depth validation of the bistatic
lidar system and its measurement uncertainty. To this end, a new, specially
designed wind tunnel with a laser Doppler anemometer (LDA) as flow velocity
reference has been erected on a platform at a height of 8 m; this allows the
new wind lidar to be positioned below the wind tunnel test section to be
validated for wind vector measurements that are traceable to the SI units. A
first validation measurement within the wind tunnel test section is
presented, showing a deviation between the bistatic lidar system and the LDA clearly
below 0.1 %.
Funder
Bundesministerium für Wirtschaft und Energie
Subject
Electrical and Electronic Engineering,Instrumentation
Reference19 articles.
1. Albers, A., Janssen, A. W., and Mander, J.: How to gain acceptance for lidar measurements, available at: https://www.windguard.de/veroeffentlichungen.html (last access: 4 January 2019), 2010. a
2. Bingöl, F., Mann, J., and Foussekis, D.: Conically scanning lidar error in complex terrain, Meteorol. Z., 18, 189–195, https://doi.org/10.1127/0941-2948/2009/0368, 2009. a
3. Bradley, S.: Wind speed errors for LIDARs and SODARs in complex terrain, IOP Conf. Ser. Earth Environ. Sci., 1, 012061, https://doi.org/10.1088/1755-1307/1/1/012061, 2008. a
4. Bradley, S., Strehz, A., and Emeis, S.: Remote sensing winds in complex terrain – a review, Meteorol. Z., 24, 547–555, https://doi.org/10.1127/metz/2015/0640, 2015. a
5. Drain, L. E.: The Laser Doppler Technique, John Wiley & Sons Ltd, 1980. a
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献