Quantitative measurement of combustion gases in harsh environments using NDIR spectroscopy
-
Published:2019-03-01
Issue:1
Volume:8
Page:123-132
-
ISSN:2194-878X
-
Container-title:Journal of Sensors and Sensor Systems
-
language:en
-
Short-container-title:J. Sens. Sens. Syst.
Author:
Niklas Christian, Bauke Stephan, Müller Fabian, Golibrzuch Kai, Wackerbarth Hainer, Ctistis GeorgiosORCID
Abstract
Abstract. The global climate change calls for more environmentally friendly use of
energy and has led to stricter limits and regulations for the emissions of
various greenhouse gases. Consequently, there is nowadays an increasing need
for the detection of exhaust and natural gases. This need leads to an
ever-growing market for gas sensors, which, at the moment, is dominated by
chemical sensors. Yet, the increasing demands to also measure under harsh
environmental conditions pave the way for non-invasive measurements and thus
optical detection techniques. Here, we present the development of two optical
detection systems using non-dispersive infrared absorption spectroscopy
(NDIR). One system is intended for civilian use, capable of detecting both CO
as well as CO2 in the range of 4–5 µm. Furthermore,
restrictions regarding size and economic viability are put on this sensor so
it can compete with existing sensors. For CO2, an estimated
resolution of 444 ppm is achieved, which is competitive with established
sensors on the market. For CO an estimated resolution of 1401 ppm was
achieved, rendering it necessary to improve this sensor to be competitive
with other available sensors. The second system is used in an exhaust system
and is capable of detecting CO2 at 3.2 µm facing
cross-sensitivity with H2O. A data analysis method is described to
separate the CO2 and H2O signals, revealing a time resolution
of 33 µs.
Publisher
Copernicus GmbH
Subject
Electrical and Electronic Engineering,Instrumentation
Reference30 articles.
1. Bauke, S., Golibrzuch, K., Rotter, F., Wackerbarth, H., Thiele, O., and Berg, T.: Quantitative, time-resolved detection of CH4 concentrations in flows for injection analysis in CNG engines using IR absorption, J. Sens. Sens. Syst., 6, 185–198, https://doi.org/10.5194/jsss-6-185-2017, 2017. a 2. Bauke, S., Golibrzuch, K., Wackerbarth, H., Fendt, P., Zigan, L., Seefeldt, S., Thiele, O., and Berg, T.: Optical sensor system for time-resolved quantification of methane concentrations: Validation measurements in a rapid compression machine, J. Quant. Spectrosc. Ra., 210, 101–110, https://doi.org/10.1016/j.jqsrt.2018.02.016, 2018. a, b, c, d, e, f, g 3. Dooly, G., Clifford, J., Leen, G., and Lewis, E.: Mid-infrared point sensor for in situ monitoring of CO2 emissions from large-scale engines, Appl. Optics, 51, 7636–7642, https://doi.org/10.1364/AO.51.007636, 2012. a 4. Ernst, A. and Zibrak, J. D.: Carbon monoxide poisoning, New Eng. J. Med., 339, 1603–1608, 1998. a 5. European Parliament and Council: Regulation No 443/2009, setting emission performance standards for new passenger cars as part of the Community's integrated approach to reduce CO2 emissions from light-duty vehicles, available at: http://eur-lex.europa.eu/legal-content/EN/TXT/PDF/?uri=CELEX:02009R0443-20140408&from=EN (last access: 27 February 2019), 2009. a
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|