In Vitro Comparison of the New In-Line Monitor BMU 40 versus a Conventional Laboratory Analyzer

Author:

Grosse F. Oliver,Holzhey David,Falk Volkmar,Schaarschmidt Jan,Kraemer Klaus,Mohr Friedrich W.

Abstract

Reliable information about different blood parameters is essential in maintaining hemodynamics, perfusion, and gas exchange during cardiopulmonary bypass (CPB). For this purpose, a precise and continuous monitoring is needed. The objective of this in vitro study was to compare a novel continuous in-line blood parameter monitoring system versus a reference laboratory analyzer. The study was conducted as an in vitro prospective experimental study during a CPB simulation. The reliability of BMU 40 was tested in monitoring the pO2, oxygen saturation (SO2), and hematocrit (Hct) under physiological and extreme conditions with regards to temperature, oxygenation, and blood concentration. Four different tests were performed and conducted with five sensors each. Correlation analyses and Bland-Altman analyses were performed. A total of 350 measurement points were compared. All monitored values of blood parameters correlated highly with laboratory values (all r values >.90). Test 1: Biases of pO2(act) varied from −3.24 mmHg (±6.86 mmHg) up to 6.0 mmHg (±17.89 mmHg). The biases of pO2(37°C) ranged from −3.52 mmHg (±6.01 mmHg) up to 68.8 mmHg (±67.82 mmHg). Test 2: The biases standard deviations (SD) for Hct ranged from −0.35% (±.79%) up to 2.35% (±.91%). The biases (SD) for SO2varied from −.45% (±.86%) up to .85% (±1.01%). Test 3: The biases (SD) of Hct ranged from −1.00% (±1.84%) up to −.67% (±1.49%). Test 4: The biases (SD) for SO2varied from −.36% (±1.60%) up to.48% (±.90%). The BMU 40 is a reliable device in measuring the partial oxygen pressure (pO2), SO2, and Hct under normal physiological and extreme conditions with regards to temperature, oxygenation, and blood concentration in simulation of CPB. The algorithm to calculate pO2(37°C) under hypothermic conditions needs to be adjusted. (Before the official market launch a new software version of the BMU 40 has been developed. The algorithm to calculate pO2(37°C) under hypothermic conditions has been improved and the miscalculation eliminated.)

Publisher

EDP Sciences

Subject

Cardiology and Cardiovascular Medicine,Health Professions (miscellaneous),Medicine (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3