Author:
Li He,Zhang Yanchi,Xie Da,Wang Maoye
Abstract
Aiming at the problem of low redundancy in the structure of the cascaded H-bridge STATCOM. This paper studies and designs a cascaded H-bridge STATCOM device based on STM32 distributed control. The article introduces the basic topology of the device and the realization principle of the control system. The turn-on and turn-off time of the MOSFET in each H-bridge is calculated by using the law of minimum harmonics, realize the output of the fitted sine wave. A simulation model of 12H bridge cascade is built in the EMTP power system electromagnetic transient analysis simulation software. The simulation results show the correctness and reliability of the design.
Reference5 articles.
1. Hatano N, Ise T. A configuration and control method of cascade H-bridge STATCOM[C]// Power and Energy Society General Meeting Conversion and Delivery of Electrical Energy in the, Century. IEEE, 2008:1-8.
2. Ying C, Qiang G, Xu D. Control and performance of a medium-voltage cascade H-bridge STATCOM[C]// Power Electronics and Motion Control Conference. IEEE, 2012:2995-2999.
3. Busarello T, Mortezaei A, Morales-Paredes H, et al. Simplified Small-Signal Model for Output Voltage Control of Asymmetric Cascaded H-Bridge Multilevel Inverter[J]. IEEE Transactions on Power Electronics, 2017.
4. Zhang C, Geng H, Li S, et al. Hybrid communication topology and protocol for distributed-controlled cascade H-bridge multilevel STATCOM[C]// International Conference on Electrical Machines and Systems. IEEE, 2015:597-602.
5. Reddy C L, Kumar P S, Sushama M, et al. A five level cascaded H-bridge multilevel STATCOM[C]// Microelectronics and Electronics. IEEE, 2016:36-41.