Energy savings potential from prismatic glass structure

Author:

Shemelin Viacheslav,Matuska Tomas,Sourek Borivoj,Jirka Vladimir

Abstract

The simulation analysis of the potential energy savings from the prismatic glass structure has been provided. The two conventional triple glazings and two proposed triple glazings with prismatic glass have been experimentally tested to obtain the realistic angular selective optical properties. The experimental results have been compared with conventional triple glazing with clear glass panes and triple glazing with solar control pane applied. The comparison indicated high potential advantages of triple glazing with prismatic glass structures (especially for reverse symmetrical prism): low transmittance for high solar altitude–summer condition, high transmittance for low solar altitude–winter condition. The obtained transmittance characteristics were used as input data for the annual simulation of a typical office in the Czech Republic. The simulation has been performed in TRNSYS and TRNBuild software. The gathered results confirmed, that prismatic glass structure can bring energy savings for both cooling and heating energy demands.

Publisher

EDP Sciences

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术