Effect of Office Design Characteristics and Anthropometrics on Thermal Comfort in Malaysian Universities Air-Conditioned Buildings

Author:

Md Taib Noor Syazwanee,Zaki Sheikh Ahmad,Rijal Hom Bahadur,Abd Razak Azli,Yakub Fitri,Mat Ali Mohamed Sukri,Othman Nor’azizi

Abstract

Apart from indoor environmental and personal factors, contextual factors have significantly influenced several thermal comfort studies. In air-conditioned spaces, thermal comfort is conveniently attainable by adjusting the temperature settings, but indoor design elements might alter thermal perceptions and provide adaptive opportunities. This study examines the influence of office design characteristics and anthropometrics on thermal comfort parameters and perceptions. Nineteen university offices in Kuala Lumpur and Shah Alam, comprised of twelve shared and seven private spaces, were investigated, and 628 responses were collected from 42 participants with even gender distributions. The results showed that room occupancy and size were statistically significant with Griffiths’ comfort temperature. Offices with five or more people had lower mean comfort temperature (24.1 ℃) than private offices (25.0 ℃). The mean comfort temperature in offices larger than 80 m2 was 23.7 ℃ with warmer thermal preference, while offices smaller than 40 m2 were approximately one-degree Celsius higher. Offices with no shading device, window blinds opened, and tiled floorings had mean comfort temperatures higher than 25.0 ℃. The findings also indicated that offices with more than a 60% glazing ratio have a slightly higher mean comfort temperature at 24.9 ℃. The thermal sensation during closed blinds was much cooler than opened ones. The anthropometry of the human body impacts how heat is regulated; thus, respondents with higher Body Mass Index (BMI) and above-average body surface area (higher than 1.7 m2) had significantly lower comfort temperatures and preferred more humid surroundings. Mean comfort temperature was statistically significant with BMI with a noticeable difference between underweight (25.1 ℃), normal (24.5 ℃), and obese (23.9 ℃) BMIs. In this study, it is recommended that BMI be considered when positioning occupants in shared offices, and window blinds are an integral shading device for adjusting indoor thermal comfort levels.

Publisher

EDP Sciences

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3