Ceiling-Fan-Integrated Air Conditioning (CFIAC): Age-of-air, Air Pollution, and Airflow Distribution

Author:

Li Lu,Chen Wenhua,Zhang Hui,He Yingdong,Arens Edwards,Fung Jimmy C.H.,Lau Alexis K.H.

Abstract

Ceiling-Fan-Integrated-Air Conditioning (CFIAC) is a heating ventilation and air conditioning (HVAC) design approach that jets supply air into the vicinity of ceiling fans to be mixed and distributed within the room. This eliminates terminal ductwork and diffusers and provides very efficient cooling for the occupants. Two previously published papers have described the air velocity, temperature, and thermal comfort fields in a space conditioned by CFIAC. This paper is the third in this series, to evaluate CFIAC ventilation effectiveness and its effect on air pollution. In a test chamber, HVAC supply air was jetted from a high-sidewall vent into the centreline of a ceiling fan. The ceiling fan was operated at various conditions (off, level 2-downward, level 4-downward, and blowing upward). Carbon dioxide (CO2) was used as a tracer gas for the age-of-air evaluation, and as a proxy for an indoor air pollutant. For the age-of-air measurement, the CO2 source was injected into the side wall jet, and the age-of-air was monitored in various locations in the chamber. For the air pollution test, CO2 as the pollution source was released near a thermal manikin’s nose that was located in the middle of the chamber. The CO2 concentrations were measured at different locations around the ceiling fan and the thermal manikin. The ventilation effectiveness and health exposure are represented by the age-of-air and intake fraction (IF). At level 2 and level 4 downward fan operations, the age-of-air is reduced in the measured locations compared to the fan-off operation. The age-of-air for upward fan operation is equal to the age-of-air in fan-off operation, except for one location that is farthest from the fan. The IF results are very similar among all 4 fan operations, with level-4-downward and upward-fan operations slightly lower than the fan level-2 downward and fan-off operations. The study is considered preliminary, but at this point, we can say that fans reduce age-of-air and cross-infection risk.

Publisher

EDP Sciences

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3