Author:
Zhang Ying,Olofsson Thomas,Nair Gireesh,Zhao Chenbo,Yang Bin,Li Angui
Abstract
With access to modern building technologies and HVAC-systems, it is possible to obtain low energy use and good thermal comfort for complex design, such as large building volumes. However, the situation is different for large single zone buildings with large volumes. They often have insufficient thermal comfort. The problem could be partially attributed to the unwanted airflows due to the cold surfaces, especially the windows. With increased knowledge of the airflow, it is possible to identify suitable renovation strategies in such buildings. In this work, we study a church building with mechanical air change system and floor heating. CFD-simulations with dynamic airflow was conducted based on building geometries and technical data. The validation was based on data from the ventilation control and the space-heating system. The results show how the window-to-wall ratios and the positions of windows affect the thermal comfort. It contributes with knowledge of advantages and disadvantages of different envelope design in the existing environment with floor heating.
Reference14 articles.
1. Draught risk from cold vertical surfaces
2. Eckert E.R.G., Jackson T.W.. NACA Report 1015, (1951).
3. Subway Environmental Design Handbook. (1976)