Author:
Pavlenko Aleksandr,Zhukov Vladimir,Pecherkin Nikolay,Slesareva Ekaterina,Boyadjiev Christo,Dzhonova-Atanasova Daniela
Abstract
Structured packings are widely used in distillation columns to separate various types of mixtures. These packings have an ordered structure, which ensures more uniform conditions for interaction of counter-current flows of liquid and vapor than in the random packings and have a small hydraulic resistance. Nevertheless, in columns with a diameter of more than 0.5 m, formation of large-scale non-uniformity in distribution of liquid and vapor flow parameters over the packing cross-section is observed. In this work, experimental data on formation of large-scale non-uniformity in the temperature field over the cross-section of the Sulzer 500X packing, as well as on the efficiency of mixture separation and the pressure drop across the packing were obtained. The experiments were carried out with separation of R114/R21 freon mixture on a 10-layer structured packing Sulzer 500X with a diameter of 0.6 m and a height of 2.2 m. Experimental data were compared with the results obtained earlier for a structured packing Mellapack 350.Y with a diameter of 0.9 m and a height of 2.1 m. The presented experimental data will be used to construct and verify a new model of mass transfer and efficiency of mixture separation in the large-scale distillation packed columns.