Author:
Plotnikova L. V.,Chilikova I. I.,Sitnikov S. Y.,Ukhlin V. E.,Efremov G. I.,Kislov A.P.
Abstract
The results of computer simulation of industrial processes of separation of substances with the inclusion of a heat pump are presented. Designs of heat pumps of closed type, open type, like “pipe in pipe” are considered. In the simulation software Aspen HYSYS, the adequacy of the computer model of the “rectification unit – closed type heat pump” system was checked. The results of computer simulation of the “rectification unit – open-type heat pump ’pipe in pipe’” system are presented. This system allows to increase the efficiency of the unit by 9% compared with the system of separation of substances with the inclusion of an open-type heat pump and by 14% compared with a system with the inclusion of a closed-type heat pump.
Reference15 articles.
1. Modeling and Modernization of Industrial Desulfurizing Packed Columns at Refineries
2. Improving the Efficiency of Gas-Separation Units in Ethylene Production
3. Investigation of energy-saving azeotropic dividing wall column to achieve cleaner production via heat exchanger network and heat pump technique
4. Plotnikova L V, Kostyleva E E, Chilikova I I and Sitnikov S Y 2019 The use of heat pump installations as part of waste energy convertion complexes in the joint generation of electrical and thermal energy IOP Conf. Series: Earth and Environmental Science, Int. Scientific Conf. “Efficient waste treatment – 2018” (13-14 December, 2018) p. 012067
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献