Chen Kongliang,Yuan Guoqing,Wang Liankun
Abstract
The steel roof of the West Stand structure in Jiangmen Sports Center is a super-span space steel tube truss arch structure. In this article, the simulation analysis, and construction monitoring process, and the arch foot deformation monitoring is researched systematically, and the fuzzy reliability analysis is established based on the construction monitoring process. The monitoring results show that the roof structure is in healthy state, and the arch foot deformation meets the design requirements, which means that detailed simulation calculation provides theoretical basis for construction monitoring, and the measured data agree well with the theoretical data. Reliability Fuzzy Comprehensive Evaluation of structural monitoring adopts a layered weighting method by dividing the entire structural monitoring into several types of key monitoring indicators, corresponding analysis is carried out according to the calculation formula of the weight of various indicators to solve the reliability problem of structural monitoring. It is shown through analysis that this method can provide an effective basis for on-site safety construction, and the above conclusions can provide references for related projects in the future.
Cited by
1 articles.
订阅此论文施引文献