Author:
Mansurov Rustam,Rafalskaya Tatyana,Efimov Dmitry
Abstract
A screened enclosing structure of the outer wall of the building without the use of thermal insulation materials is proposed. To ensure the required thermal resistance of the outer fence, screens (cement-containing slabs) and closed air gaps between them are used. Using the ANSYS software package, the heat transfer processes were modeled in a shielded building envelope, consisting of the main (carrier) part and screens with air gaps closed between them. The features of the heat transfer process in the thickness of the outer enclosure are revealed.
Reference7 articles.
1. Fokin KF 2006 Construction heat engineering of the enclosing parts of buildings (Moscow: AVOK-PRESS) p 256
2. Chaplin VM 1905 The course of heating and ventilation (Moscow: GOSIZDAT) p 376
3. Danilov MN and Fedorova NN 2014 Numerical study of the heat-shielding characteristics of building sandwich panels Mag. Engineering Physics Journal T 87 No 5 pp 1096-1105
4. Kalitkin NN 1978 Numerical methods (Moscow: Science) p 512
5. Samarskiy AA and Gulin AV 1989 Numerical methods (Moscow: Science) p 432