Correlation between cephalic screw positioning of Standard Gamma 3 Nail for intertrochanteric fractures and cut-out incidence

Author:

Ortolani Alessandro,Lana DeboraORCID,Martucci Antonio,Pesce Francesco,Stallone Stefano,Milani Lorenzo,Urso Roberto,Melucci Giuseppe,Tigani Domenico

Abstract

Introduction: Lateral fractures of proximal femur are the most frequent fractures in elderly people. Internal fixation using medullary nails is the gold standard of treatment (Gamma 3 nail is the most implanted device) due to reduced incidence of complications than other devices. We report our experience in treating this kind of fractures with Gamma 3 nail, between January 2015 and December 2021. Methods: We performed a retrospective cohort study of patients treated in our orthopaedic department; level of clinical care is III: 559 patients (431 females and 128 males, with an average age of 85.3 years) with lateral femoral neck fracture. All patients were surgically treated with Gamma 3 standard nail (SGN). We evaluated preliminary X-rays to classify fractures, according to AO-OTA classification and post-operative X-ray to verify cephalic screw position site, according to areas described by Cleveland in 1959: we measured tip-to-apex distance (TAD) and tip-to-apex calcar referred distance (CalTAD). Finally Chang reduction quality criteria (CRQC) for fracture reduction of trochanteric fractures were determined using preoperative or postoperative Antero-Posterior (AP) and lateral radiographs in a Picture Archiving and Communication System (PACS). Incidence of cut-out was evaluated in relation with these parameters. Patients were divided into 2 groups: first group had cephalic screw in optimal positions (5-8-9), the other group had cephalic screw in other positions. Results: In 328 patients (58.7%) screw was in positions 5-8-9, in 231 patients (41.2%) screw was in not-optimal position. Median TAD was 19.1 ± 7.0 mm (range = 0.0–50.5); in 463 patients (82.8%) TAD was ≤ 25 mm. Median CalTAD was 21.4 ± 4.7 mm (range = 5.7–39.2); in 105 patients (79.4%) CalTAD was ≤ 25 mm. Cut-out was observed in 8 cases (1.43%). Multivariate analysis showed a significant correlation (p < 0,05) between incidence of cut-out and fracture type 31A2 and with TAD values >25 mm. Cephalic screw position did not influence incidence of cut-out. Discussion: In order to obtain fracture healing with a low risk of failure, in particular cut-out, it is necessary to obtain good reduction of fracture and optimal lag screw position in order to achieve a TAD inferior to 25 mm.

Publisher

EDP Sciences

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3