Abstract
This paper presents the sizing and the comparison of two synchronous machines. The purpose is to design a high temperature dedicated machine with the same performance and volume as a permanent magnet machine. To compare the machines, torque has been chosen as a reference indicator and not the efficiency which will be not so good for the high temperature machine. A salient pole wound rotor is chosen with anodized aluminum tape as windings. Works presented should be considered as preliminary studies leading to the conception of a prototype.
Subject
Condensed Matter Physics,Instrumentation,Electronic, Optical and Magnetic Materials
Reference22 articles.
1. High temperature machines: topologies and preliminary design
2. Electrical Machines and Drives for Electric, Hybrid, and Fuel Cell Vehicles
3. Performance of interior permanent magnet motor drive over wide speed range
4. Huber T., Peters W., Böcker J., in
IPEC-Hiroshima 2014 − ECCE Asia, Hiroshima, Japan
(2014), pp. 1508–1515
5. Marcin L., Komeza K., Napieralska-Juszczak E., Roger D., Napieralski P., COMPEL (2019)