Coagulopathy Characterized by Rotational Thromboelastometry in a Porcine Pediatric ECMO Model

Author:

Reed Christopher R.,Bonadonna Desiree,Everitt Jeffrey,Robinson Victoria,Otto James,Tracy Elisabeth T.

Abstract

Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is used to support patients with reversible cardiopulmonary insufficiency. Although it is a lifesaving technology, bleeding, inflammation, and thrombosis are well-described complications of ECMO. Adult porcine models of ECMO have been used to recapitulate the physiology and hemostatic consequences of ECMO cannulation in adults. However, these models lack the unique physiology and persistence of fetal forms of coagulation factors and fibrinogen as in human infants. We aimed to describe physiologic and coagulation parameters of piglets cannulated and supported with VA-ECMO. Four healthy piglets (5.7–6.4 kg) were cannulated via jugular vein and carotid artery by cutdown and supported for a maximum of 20 hours. Heparin was used with a goal activated clotting time of 180–220 seconds. Arterial blood gas (ABG) was performed hourly, and blood was transfused from an adult donor to maintain hematocrit (Hct) > 24%. Rotational thromboelastometry (ROTEM) was performed at seven time points. All animals achieved adequate flow with a patent circuit throughout the run (pre- and post-oxygenator pressure gradient <10 mmHg). There was slow but significant hemorrhage at cannulation, arterial line, and bladder catheter sites. All animals required the maximum blood transfusion volume available. All animals became anemic after exhaustion of blood for transfusion. ABG showed progressively declining Hct and adequate oxygenation. ROTEM demonstrated decreasing fibrin-only ROTEM (FIBTEM) clot firmness. Histology was overall unremarkable. Pediatric swine are an important model for the study of pediatric ECMO. We have demonstrated the feasibility of such a model while providing descriptions of physiologic, hematologic, and coagulation parameters throughout. Weak whole-blood clot firmness by ROTEM suggested defects in fibrinogen, and there was a clinical bleeding tendency in all animals studied. This model serves as an important means to study the complex derangements in hemostasis during ECMO.

Publisher

EDP Sciences

Subject

Cardiology and Cardiovascular Medicine,Health Professions (miscellaneous),Medicine (miscellaneous)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3