Update on Pediatric Perfusion Practice in North America: 2005 Survey

Author:

Groom Robert C.,Froebe Shane,Martin Janine,Manfra Michael J.,Cormack John E.,Morse Catherine,Taenzer Andreas H.,Quinn Reed D.

Abstract

The devices and techniques used for pediatric cardiopulmonary bypass (CPB) undergo continuous change. New techniques and clinical comparisons of devices are frequently reported in the literature; however, information about the extent to which these techniques and devices are adopted into clinical practice at pediatric heart centers are not well described. We conducted a mail survey of North American pediatric cardiac surgery centers to gain perspective on the extent to which various devices and techniques were used for CPB along with program demographic data. In January 2005, surveys were mailed to 180 North American open heart centers. The survey was nearly identical in format and content to three earlier surveys completed in 1989, 1994, and 1999, with the exception that new questions were added to address new techniques and devices that have emerged over the years. Responses were received from 76 hospitals, for an overall response rate of 42%. Of the responding centers, 53 were performing pediatric open heart surgery and 23 were not. Twenty centers performed only pediatric open heart surgery, and 33 performed both pediatric and adult open heart surgery. The mean pediatric annual caseload of responding centers was 195 procedures/yr (range, 20–650 procedures/yr; median, 154 procedures/yr). A total of 9943 pediatric open heart procedures were performed at responding centers in 2004. Most of the centers surveyed reported use of an open venous reservoir system (88%), use of roller pumps (90%), and use of arterial line filtration (98%). Most centers used circuits that have surface treatments with heparin or some other surface-modifying agent (74%). There has been an increase in the use of all types of safety devices. Modified ultrafiltration is used at 75% of the centers surveyed. Centers reported an increase in the availability of all types of cardiac support devices including extracorporeal membrane oxygenation for postcardiotomy cardiac support (90%). This survey provides an overview of clinical practice in 2004. The series of surveys document the historical progression of clinical practice over the past 16 years. Practice surveys may also be useful for identifying gaps between evidence-based knowledge and clinical practice. These surveys document the diffusion of innovation related to CPB during the past 16 years and areas of variation in practice that need further study.

Publisher

EDP Sciences

Subject

Cardiology and Cardiovascular Medicine,Health Professions (miscellaneous),Medicine (miscellaneous)

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3