North American Neonatal Extracorporeal Membrane Oxygenation (ECMO) Devices: 2002 Survey Results

Author:

Lawson D. Scott,Walczak Rich,Lawson Andrea F.,Shearer Ian R.,Ing Richard,Schulman Scott,Kern Frank,Jaggers James

Abstract

In mid 2002, surveys of active extracorporeal membrane oxygenation (ECMO) centers in the United States and Canada were conducted via E-mail regarding neonatal equipment and personnel. Seventy-four out of 99 (75%) North American ECMO centers listed in the Extracorporeal Life Support Organization (ELSO) directory responded to the survey. Of the responding centers, 95% use roller pumps, and the remaining 5% use centrifugal pumps. Silicone membrane oxygenators were used by 97% of the respondents, while 3% used hollow fiber oxygenators. Of the silicone membrane oxygenator users, 82% used the Medtronic ECMOtherm heat exchanger, 15% used a Gish heat exchanger, and 3% used the Dideco D720 heat exchanger. Sixty-one percent of the responding centers used some form of in-line blood gas monitoring. Five percent of the centers used a bubble trap in the arterial line, and 12% used an arterial line filter. A bladder was used by 92% of the centers, and 29% used a mechanical bladder box for servo regulation, the remaining 71% used pressure servo regulation. An air bubble detector was used by 65% of the responding centers, although 81% had the device available. Heparin coating was used by 5% of the centers on all their neonatal ECMO patients. The average low range ACT was 183 seconds, and the average high range ACT was 216 seconds. At 49% of the responding centers, perfusionists were involved with the ECMO program, registered nurses were involved at 84% of the centers, and respiratory therapists were involved at 61% of the centers, perfusion assistants were involved at one center (1%), and biomedical engineers were involved at one of the centers. When compared to a 1990 survey, a shift away from using bladder boxes and toward using air bubble detectors is apparent. But other than those two shifts, ECMO is done in much the same manner as it was done 12 years ago.

Publisher

EDP Sciences

Subject

Cardiology and Cardiovascular Medicine,Health Professions (miscellaneous),Medicine (miscellaneous)

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3