The practice of cardiovascular surgery demands daily interface with sophisticated technologies including most commonly the cardiopulmonary bypass (CPB) machine. Although other industries have recognized the importance of considering human factors in the design of machines to reduce operator error, the evolution of the CPB machine over the past half-century has been characterized by incremental modifications of component parts with attention principally to mechanical efficiency and biocompatibility, but with little awareness of the impact of design changes on the human user. As a first step in the redesign of a safer pump, systematic observations of perfusionists during 10 adult and pediatric cases were conducted by staff cardiac surgeons and by human factors experts. Observations were classified according to accepted ergonomics principles. Perfusionists also performed usability evaluations and provided feedback concerning the design and functionality of bypass machines. Problems identified clustered around several usability themes. Issues with displays (8% of total comments) included location, legibility, format, and integration. Multiple problems with controls (11% of total comments) including location, sensitivity, and shape were identified, as were issues with audible alarms (6% of total comments). Component integration (14% of comments) and workspace design (21% of comments) were suboptimal as well. Procedural and communication issues (21% of comments) related to pump utilization, rather than pump design, were also identified, which stemmed from a lack of standardized operating room practices. Clinical issues (14% of comments) surrounding care of the patient were also identified but were not further analyzed, because these comments did not pertain to the design of the perfusion pump. Our observations confirmed the hypothesis that opportunities exist to incorporate usability and ergonomics insights into CPB machine design to optimize the human/technology interface. Such fundamental design considerations may improve the safety of the conduct of CPB and, consequently, outcomes after cardiovascular surgery.

Publisher

EDP Sciences

Subject

Cardiology and Cardiovascular Medicine,Health Professions (miscellaneous),Medicine (miscellaneous)

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Redesigning the operating room for safety;Handbook of Perioperative and Procedural Patient Safety;2024

2. Using Digital Biomarkers for Objective Assessment of Perfusionists’ Workload and Acute Stress During Cardiac Surgery;Bioinformatics and Biomedical Engineering;2023

3. Establishing a Ventilator–Heart Lung Machine Communication Bridge to Mitigate Errors when Weaning from Bypass;The Journal of ExtraCorporeal Technology;2019-03

4. From the Editor;The Journal of ExtraCorporeal Technology;2009-06

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3