Evaluation of Low Dose Silicon Carbide Temperature Monitors

Author:

Davis K. L.,Gusarov A.,Unruh T. C.,Calderoni P.,Heidrich B.J.,Verner K. M.,Al Rashdan A.,Lambson A. A.,Van Dyck S.,Uytdenhouwen I.

Abstract

Thermocouples are generally used to provide real-time temperature indications in instrumented tests performed at materials and test reactors. Melt wires or paint spots are often included in such tests as an independent technique of detecting peak temperatures incurred during irradiation. In addition, less expensive static capsule tests, which have no leads attached for real-time data transmission, often rely on melt wires and paint spots as a post-irradiation technique for peak temperature indication. Unfortunately, these techniques are limited in that they can only detect whether a single temperature is or is not exceeded. Silicon carbide (SiC) monitors are advantageous because a single monitor can be used to determine the peak temperature reached within a relatively broad range (200 – 800°C). Although the use of SiC monitors was proposed more than five decades ago, the ultimate performance limits of this technique are not fully understood. The Nuclear Science User Facilities (NSUF) is the United States Department of Energy Office of Nuclear Energy's only designated nuclear energy user facility. Its mission is to provide nuclear energy researchers access to world-class capabilities and to facilitate the advancement of nuclear science and technology. This mission is supported by providing access to state-of-the-art experimental irradiation testing, post irradiation examination facilities, and high performance computing capabilities as well as technical and scientific assistance for the design and execution of projects. As part of an NSUF project, low dose silicon carbide monitors were irradiated in the Belgian Reactor 2 and were then evaluated both at the SCK•CEN and at Idaho National Laboratory’s High Temperature Test Laboratory to determine their peak temperature achieved during irradiation. The technical significance of this work was that the monitors were irradiated to a dose that was significantly less than recommended in published literature. This paper will discuss the evaluation process, the irradiation test, and the performance of the low dose silicon carbide temperature monitors.

Publisher

EDP Sciences

Reference19 articles.

1. Rempe J. L., Condie K. G., Knudson D. L., and Snead L.L., Silicon Carbide Temperature Monitor Measurements at the High Temperature Test Laboratory, INL/EXT-10-17608, January 2010.

2. Snead L. L., Williams A. M., and Qualls A. L., “Revisiting the use of SiC as a Post Irradiation Temperature Monitor”, Effects of Radiation on Materials, ASTM STP 1447, Grossbeck M L., Ed, ASTM International, West Conshohocken, PA, 2003.

3. Evaluation of the continuous dilatometer method of silicon carbide thermometry for passive irradiation temperature determination

4. Method for analyzing passive silicon carbide thermometry with a continuous dilatometer to determine irradiation temperature

5. Pravdyuk N.F., Nikolaenko V.A., Karpuchin V.I., Kuznetsov V.N., Investigation of Diamond and Silicon Carbide as Indicators of Irradiation Conditions, in: Littler D.J. (Ed.), International Conference on Properties of Reactor Materials and the Effects of Radiation Damage, Butterworths, Gloucestershire, England, 1962, pp. 57–62.