Author:
Gruel A.,Ambrožič K.,Destouches C.,Radulović V.,Sardet A.,Snoj L.
Abstract
The neutron field of various irradiation positions of the TRIGA Mark II reactor of the Jožef Stefan Institute has been thoroughly characterized by neutron activation dosimetry and miniature fission chambers techniques. In order to have a fully validated calculation scheme to analyze and plan experiments, the gamma field also has to be experimentally validated. The 10-year long collaboration between CEA and JSI is a perfect framework to carry out such a study, and measurements of the gamma field started in late 2016. Several measurement techniques were investigated in in-core and ex-core positions.
On-line measurements were carried out using miniature ionization chambers manufactured by the CEA and PTW Farmer ionization chambers. Positional dependence was studied, showing a decrease in the delayed gamma contribution to the total gamma flux with increasing distance from the reactor core center.
To characterize the gamma dose in the core, as well as in the periphery, thermo- and optically stimulated luminescent detectors were tested. These detectors are commonly used at CEA to measure the gamma dose in a given material in order to study the nuclear heating in various core elements (control rod, baffle, structural material). Different filters were used in order to assess an integrated dose ranging from a few Gy up to several kGy. The feasibility of such measurements demonstrates the complementarity between measurements with dosimetry and ionization chambers from low to very high gamma-dose environment, such as in material testing reactors.
Reference12 articles.
1. Snoj L. et al., Experimental benchmarks at the JSI TRIGA Mark II reactor for validation of computer codes and nuclear data,
Proceedings, of European Research Reactor Conference,
RRFM 2018, 11-15 March
2018,
Munich, Germany.
2. Experimental assessment of the kinetic parameters of the JSI TRIGA reactor
3. Calculations to Support On-line Neutron Spectrum Adjustment by Measurements with Miniature Fission Chambers in the JSI TRIGA Reactor
4. Review of 10 years of JSI − CEA collaboration on nuclear instrumentation development,
Proceedings of 27th International Conference Nuclear Energy for New Europe,
NENE, 10-13 September
2018,
Portorož, Slovenia.
5. Measurements of miniature ionization chamber currents in the JSI TRIGA Mark II reactor demonstrate the importance of the delayed contribution to the photon field in nuclear reactors
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献