Author:
Sanchez Francisco,Albajar Ferran,Lo Bue Alessandro,Alberti Stephano,Avramidis Konstantinos,Bonicelli Tullio,Bruschi Alex,Gantenbein Gerd,Hogge Jean-Philippe,Illy Stefan,Ioannidis Zisis,Leggieri Alberto,Legrand François,Pagonakis Ioannis,Perial Etienne,Rzesnicki Tomasz,Thumm Manfred,Tigelis Ioannis
Abstract
The EU gyrotron for the ITER Electron Cyclotron (EC) heating system has been developed in coordinated efforts of the EGYC Consortium, Thales ED (TED) and Fusion for Energy (F4E) and under the supervision of ITER Organization Central Team. After the successful verification of the design of the 1MW, 170 GHz hollow cylindrical cavity gyrotron operating at the nominal TE32,9 mode with a short pulse gyrotron prototype at KIT, an industrial CW gyrotron prototype was manufactured by TED and tested at ~0.8 MW output power and 180 s pulse duration, which is the limit of the HV power supply currently available at KIT. The experiments are being continued at SPC in 2018 to extend further the pulse duration, taking advantage of the existing CW full-power capabilities of the gyrotron test facility recently upgraded for the FALCON project. The gyrotron cavity interaction is very sensitive to the alignment of the internal mechanical parts of the gyrotron tube with the magnetic field generated by the superconducting magnet within a typical range of 0.2 – 0.5 mm. The control of the tolerances and deformations becomes therefore critical to achieving the target performances. With the EU gyrotron prototype it was possible to adjust the alignment of the gyrotron tube with respect to the magnetic field axis during the installation and commissioning phase. The actual shift and tilt movements were verified using advanced metrology methods such as photogrammetry. In this paper, the alignment control techniques and procedures will be discussed also in view of enhancing the reproducibility of gyrotron performance during series production.
Reference9 articles.
1. Courtesy of S. Illy, IHM, Karlsruhe Institute of Technology (KIT).
2. Avramidis K.A. et al., Numerical investigations on the effects of electron beam misalignment on beam-wave interaction in a high-power coaxial gyrotron, 38th International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz), Mainz, Germany, 14-19 September, 2013, Conference Digest.
3. Status of the development of the EU 170 GHz/1 MW/CW gyrotron
4. Private communication from Leggieri A. (TED) and information from the TH1509 Operation Manual.
5. Validation Experiments on the 2-MW CW 170-GHz Load for the European ITER Gyrotron
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Progress on TH1509U 170 GHz 1 MW European Gyrotron Program;2022 23rd International Vacuum Electronics Conference (IVEC);2022-04-25
2. TH1509U European 170 GHZ 1 MW CW Industrial Gyrotron Upgrade;2021 22nd International Vacuum Electronics Conference (IVEC);2021-04-27