A model of spatial resolution uncertainty for Compton camera imaging

Author:

Ma Yanting,Rapp Joshua,Boufounos Petros,Mansour Hassan

Abstract

Compton cameras use a pair of detectors to record the energy deposited during Compton scattering and photoabsorption of gamma ray photons. By inverting the forward model for these detection events, the 3D radioactive source distribution can be recovered computationally. However, existing methods of describing the forward model ignore the ambiguity in the Compton cone axis introduced by the detector pixel size. In this paper, we introduce approximations to the axis ambiguity that make the description of the source ambiguity computationally tractable and improve the accuracy of the detection forward model. Specifically, we model the pixel active areas as discs, so the intersection between all possible Compton cone axes and a plane parallel to the detectors is also a disc. Because of ambiguity in the Compton cone axis, the gamma source position is constrained to lie within a more complicated volume that we approximately bound by ellipses or hyperbolas at discrete depth slices. We perform simulations of single point gamma sources using the Geant4 software. Our forward model leads to improved source distribution recovery using both backprojection and iterative reconstruction methods, demonstrating that accurate localization can be performed from a smaller number of detected photons.

Publisher

EDP Sciences

Subject

General Medicine

Reference25 articles.

1. A Quantum Theory of the Scattering of X-rays by Light Elements

2. Wilderman S., Clinthorne N., Fessler J., and Rogers W., “List-mode maximum likelihood reconstruction of Compton scatter camera images in nuclear medicine, ” in IEEE Nuclear Science Symposium and Medical Imaging Conference, Nov. 1998, vol. 3, pp. 1716–1720 vol. 3.

3. Improved modeling of system response in list mode EM reconstruction of Compton scatter camera images

4. Instrument description and performance of the Imaging Gamma-Ray Telescope COMPTEL aboard the Compton Gamma-Ray Observatory

5. 4/spl pi/ Compton imaging using a 3-D position-sensitive CdZnTe detector via weighted list-mode maximum likelihood

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3