Author:
Vitullo Fanny,Lamirand Vincent,Godat Daniel,Pautz Andreas
Abstract
The 160 MiMi neutron detectors of SAFFRON, a 3D full-core mapping system developed at EPFL for the CROCUS zero-power reactor, have been simultaneously inter-calibrated in preparation for their in-core installation. An experimental setup was built to distribute up to 180 MiMi detectors radially at 15 cm around the Pu-Be neutron source of the CARROUSEL facility. An efficient inter-calibration methodology is presented: first, the azimuthal shape of the relative source strength is characterized by rotating 18 MiMi detectors distributed every 20º around the PuBe, followed by the simultaneous determination of the relative sensitivity of 160 MiMi detectors, distributed all around the Pu-Be source.
Reference21 articles.
1. Vitullo F. et al., “Design of a 150-miniature detectors 3D core-mapping system for the CROCUS reactor, ” EPJ Web Conf., vol. 253, 2021.
2. Nuclear Energy Agency (NEA), “IRPhE Handbook 2020.” International Reactor Physics Evaluation Project Handbook (database), 2020.
3. Lamirand V., “Installation nucléaire CROCUS Rapport de sécurité, ” Techical report RT-100-104-17-48, 2017.
4. Vitullo F. et al., “Developing and testing a miniature fibercoupled scintillator for in-core neutron counting in CROCUS, ” in EPJ Web Conferences, 2020.
5. A mm3 Fiber-Coupled Scintillator for In-Core Thermal Neutron Detection in CROCUS
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献