Analysis of the Signal over Noise Ratio of the hodoscope determined by Monte Carlo calculation

Author:

Di Salvo J.,Mirotta S.,Chevalier V.

Abstract

The CABRI experimental pulse reactor, located at the Cadarache nuclear research center, southern France, is devoted to the study of Reactivity Initiated Accidents (RIA) for the purpose of the CABRI International Program (CIP), managed by IRSN in the framework of an OECD/NEA agreement. The hodoscope equipment installed in the CABRI reactor is an almost unique online fuel motion monitoring system, thanks to the measurement of the fast neutrons emitted during a power pulse by a tested rod positioned inside a dedicated test loop reproducing PWR conditions. This system is dedicated to the analysis of fuel displacement. Hence, one of the most important parameter measured by the hodoscope detectors is the Signal over Noise Ratio (SNR), characterizing the fraction of neutrons directly coming from the test rod (“signal”) over neutrons coming from the core (“noise”). It is interesting to calculate the SNR in order to define some quantitative criterions to improve hodoscope measurements and to understand if any modification linked to the test loop may significantly change this essential parameter. Another parameter of interest is the so-called “scattering coefficient”, which corresponds to the fraction of neutrons coming from the test rod and being scattered between their birth and their detection. This parameter is used to enhance the analysis of the fuel displacement which may happen during the power transient. In this article, the method used to calculate the SNR using MCNP6.2 Monte Carlo code will be detailed. Because the hodoscope detectors are located far away from the test rod (up to 4 meters), a 2D model of CABRI core and instrumentation has been implemented. No variance reduction techniques have been used to solve this problem in order to record the place of birth of neutron which contributes to the different scores with the goal to perform a detailed analysis of the SNR. This strategy allows to access numerically to the “scattering coefficient”. Finally, the comparison between calculated and measured SNR for a case study will be carried out. A quite good agreement between the 2D simulations and experiments recently performed in the CABRI reactor has been obtained.

Publisher

EDP Sciences

Reference6 articles.

1. Reactivity Initiated Accident transient testing on irradiated fuel rods in PWR conditions: The CABRI International Program

2. “Renovation, improvement and experimental validation of the Helium-3 transient rods system for the reactivity injection in the CABRI reactor”. Duc B. et al. Proc of IGORR 2014 conference, Bariloche, Argentina, November 2014

3. “The CABRI fast neutron Hodoscope: Renovation, qualification program and first results following the experimental reactor restart”. Chevalier V., Mirotta S., Guillot J., Biard B. EPJ Web of Conferences, Volume 170, 10 January 2018

4. “MCNP® user’s manual. Code version 6.2. Manual Rev. 0” Werner C. J. editor. LA-UR-17-29981. October 27, 2017

5. “The CABRI fast neutron Hodoscope: calibration campaign results”. Chevalier V., Mirotta S., Monchalin N., Guillot J. The European Research Reactor Conference, the annual gathering of the research reactor community in Europe, RRFM, Oct 2020, HELSINKI (on line), Finland. (https://hal.archives-ouvertes.fr/hal-03080772).

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com