Neutron Coincidence Measurements and Monte Carlo Modelling of Waste Drums Containing Reference Nuclear Material

Author:

Borella A.,Rossa R.,Boden S.,Bruggeman C.,Rogiers B.,Smets S.,Valcke E.

Abstract

Within the EC-funded CHANCE project several non-destructive techniques are being considered for the assay of waste bearing drums. Such techniques include calorimetry, gamma-ray spectrometry and neutron coincidence counting. The aim is to quantify uncertainties on the inventory of radionuclides, and how these are potentially reduced by combining the signatures from different techniques in the data analysis. In this framework, neutron coincidence measurements were carried out with two slab counters based on 3He detectors coupled to shift register electronics. Such a system consists of two identical slabs with 6 detectors each, and is transportable, rather compact and flexible in terms of sizes and geometries that can be measured. With this system three 200 L drums containing certified reference nuclear material and different filling materials were measured. The certified nuclear material was in the form of 21 pellets of mixed oxide of U and Pu with a total mass of about 10.5 g; in addition, a single pellet of about 10.05 g was also available. The pellets could be placed in predefined positions within the drum in a reproducible way. The geometry and composition of the three drums was well characterized and consisted of Ethafoam, a mixture of Ethafoam, stainless steel and PVC, and mortar with an inner core of extruded polystyrene. The measurement setup was arranged such that the drum was placed between the two slab counters. The positions of the slab counters relative to the drum were accurately measured before each measurement, and a dedicated system was used to minimize the uncertainty on the detector positioning. The measurement data were first analysed by applying the point model of Hage and the mass of nuclear material in the drum was determined from the rate of totals and reals and the radionuclide composition. Due to the fact that not all the point model conditions were met, we found that the point model overestimates the mass up to about 50%. In addition, a Monte Carlo model of the measurement geometry was developed using the MCNP code. The model was used to determine a calibration factor between the reals rate and the mass of the sample. Measurements with a calibrated 252Cf source were used to verify the model. With a Monte Carlo based approach the mass of the mixed oxide pellets is within a few percent from the nominal values, except for strongly asymmetrical configurations where the deviation is up to about 20%. The results reveal the importance of an accurate background correction and of accounting for surrounding materials of the building such as walls, floor and ceiling in the Monte Carlo model.

Publisher

EDP Sciences

Reference22 articles.

1. Available online: https://www.micado-project.eu/. Last accessed 28/04/2021.

2. Evaluation of measurement data — Guide to the expression of uncertainty in measurement, JCGM 100:2008, First edition September 2008, available at https://www.iso.org/sites/JCGM/GUM/JCGM100/C045315e-html/C045315e.html?csnumber=50461

3. Ensslin E., 1991. “Principles of Neutron Coincidence Counting” in Passive Nondestructive Assay of Nuclear Materials, NuREG/CR-5550, LA-UR-90-732.

4. Models for a three-parameter analysis of neutron signal correlation measurements for fissile material assay

5. Menlove H. O., 1991. “Neutron coincidence instruments and applications”. in Passive Nondestructive Assay of Nuclear Materials, NuREG/CR-5550, LA-UR-90-732.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3