Measuring gamma doses over the mGy-kGy range with a single type of TLD detector

Author:

Gruel Adrien,Sardet Alix,Chaussonnet Vincent,Houdouin-Quenault Maxime,Garnier Daniel

Abstract

Thermo-luminescent detectors are currently used to measure gamma doses in the medical and environmental surveillance fields. During the past few years, the CEA Reactor Studies Division tested and validated the use of these detectors for gamma flux characterization and nuclear heating measurements in mixed neutron/gamma fields of low power reactors. Doses were comprised between a few mGy and a few Gy for dose rates up to a few Gy.h-1. However, in MTR or TRIGA reactors, the gamma flux level is much higher (> 1012 n/cm2/s) and the TLD currently in use (CaF2:Mn and 7LiF:Mg,Ti) and their readout protocols were no longer suitable for the resulting doses. In order to extend the applicable dose range up to ∼1 MGy (dose rate of a few kGy.h-1), several options were explored. On one side, some adjustments were made to the readout protocols of CaF2:Mn and 7LiF:Mg,Ti, notably by testing the use of filters to reduce the amount of light received by the reader PMT to avoid saturation. On the other side, a new type of TLD (LiF:Mg,Cu,P) with different Li enrichments (natural or enriched in 7Li) was tested. This paper presents the calibration measurements results performed in pure gamma fields, at the irradiation platform of the CEA Cadarache Radioprotection Division, between 250 mGy and 3 Gy for all detector types. In addition to the calibration, these measurements also studied the Mg,Cu,P-doped detectors response: reproducibility, dose rate dependence, incoming photon energy dependence, high temperature effect when reading TLD, etc. Results show that at low doses Mg,Cu,P-doped TLDs are slightly less stable than CaF2:Mn and 7LiF:Mg,Ti. The sensitivity modification after a high dose exposure seems to indicate that a new protocol readout should be defined for Mg,Cu,P-doped sensors (high temperature peak).

Publisher

EDP Sciences

Reference8 articles.

1. State of the art on nuclear heating measurement methods and expected improvements in zero power research reactors

2. Analysis and Recent Advances in Gamma Heating Measurements in MINERVE Facility by Using TLD and OSLD Techniques

3. Amharrak H., Développement et optimisation de méthodes de mesures d’échauffements nucléaires et de flux gamma dans les réacteurs expérimentaux : identification, maîtrise, traitement et réduction des incertitudes associées, thesis, Aix-Marseille University, 2012.

4. Development and Optimization of Nuclear Heating Measurement Techniques in Zero Power Experimental Reactors

5. Lemaire M., Validation des calculs d’échauffements photoniques en réacteur d’irradiation au moyen du programme experimental AMMON et du dispositive CARMEN, thesis, Aix-Marseille University, 2015

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3