A novel application of Fiber Bragg Grating (FBG) sensors in MPGD

Author:

Abbaneo D.,Abbas M.,Abbrescia M.,Abi Akl M.,Aboamer O.,Acosta D.,Ahmad A.,Ahmed W.,Aleksandrov A.,Altieri P.,Asawatangtrakuldee C.,Aspell P.,Assran Y.,Awan I.,Bally S.,Ban Y.,Banerjee S.,Barashko V.,Barria P.,Bencze G.,Beni N.,Benussi L.,Bhopatkar V.,Bianco S.,Bos J.,Bouhali O.,Braghieri A.,Braibant S.,Buontempo S.,Calabria C.,Caponero M.,Caputo C.,Cassese F.,Castaneda A.,Cauwenbergh S.,Cavallo F.R.,Celik A.,Choi M.,Choi S.,Christiansen J.,Cimmino A.,Colafranceschi S.,Colaleo A.,Conde Garcia A.,Czellar S.,Dabrowski M.M.,De Lentdecker G.,De Oliveira R.,de Robertis G.,Dildick S.,Dorney B.,Endroczi G.,Errico F.,Fenyvesi A.,Ferrini M.,Ferry S.,Furic I.,Giacomelli P.,Gilmore J.,Golovtsov V.,Guiducci L.,Guilloux F.,Gutierrez A.,Hadjiiska R.M.,Hauser J.,Hoepfner K.,Hohlmann M.,Hoorani H.,Iaydjiev P.,Jeng Y.G.,Kamon T.,Karchin P.,Korytov A.,Krutelyov S.,Kumar A.,Kim H.,Lalli A.,Lee J.,Lenzi T.,Litov L.,Loddo F.,Madorsky A.,Maerschalk T.,Maggi M.,Magnani A.,Mal P.K.,Mandal K.,Marchioro A.,Marinov A.,Majumdar N.,Merlin J.A.,Mitselmakher G.,Mohanty A.K.,Mohapatra A.,Molnar J.,Muhammad S.,Mukhopadhyay S.,Naimuddin M.,Nuzzo S.,Oliveri E.,Pant L.M.,Paolucci P.,Park I.,Passamonti L.,Passeggio G.,Pavlov B.,Philipps B.,Piccolo D.,Pierluigi D.,Postema H.,Primavera F.,Puig Baranac A.,Radi A.,Radogna R.,Raffone G.,Ranieri A.,Rashevski G.,Riccardi C.,Rodozov M.,Rodrigues A.,Ropelewski L.,RoyChowdhury S.,Russo A.,Ryu G.,Ryu M.S.,Safonov A.,Salva S.,Saviano G.,Sharma A.,Sharma A.,Sharma R.,Shah A.H.,Shopova M.,Sturdy J.,Sultanov G.,Swain S.K.,Szillasi Z.,Talvitie J.,Tatarinov A.,Tuuva T.,Tytgat M.,Valente M.,Vai I.,Van Stenis M.,Venditti R.,Verhagen E.,Verwilligen P.,Vitulo P.,Volkov S.,Vorobyev A.,Wang D.,Wang M.,Yang U.,Yang Y.,Yonamine R.,Zaganidis N.,Zenoni F.,Zhang A.

Abstract

We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active area each, employing three GEM foils per chamber, to be installed in the forward region of the CMS endcap during the long shutdown of LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM foils that are mechanically stretched in order to secure their flatness and the consequent uniform performance of the GE1/1 chamber across its whole active surface. So far FBGs have been used in high energy physics mainly as high precision positioning and re-positioning sensors and as low cost, easy to mount, low space consuming temperature sensors. FBGs are also commonly used for very precise strain measurements in material studies. In this work we present a novel use of FBGs as flatness and mechanical tensioning sensors applied to the wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used to determine the optimal mechanical tension applied and to characterise the mechanical tension that should be applied to the foils. We discuss the results of the test done on a full-sized GE1/1 final prototype, the studies done to fully characterise the GEM material, how this information was used to define a standard assembly procedure and possible future developments.

Publisher

EDP Sciences

Reference9 articles.

1. Abbaneo D. et al., Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System, arXiv:1412.0228v2, 8 Dec 2014.

2. Upgrade of the CMS muon system with triple-GEM detectors

3. A. Colaleo et al., CMS TECHNICAL DESIGN REPORT FOR THE MUON ENDCAP GEM UPGRADE, CERN-LHCC-2015-012. CMS-TDR-013, https://cds.cern.ch/record/2021453.

4. D. Abbaneo et al.,Status of the Triple-GEM project for the upgrade of the CMS Muon System, DOI: 10.1088/1748-0221/8/12/C12031.

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Two years’ test of a temperature sensing system based on fibre Bragg grating technology for the CMS GE1/1 detectors;Journal of Physics: Conference Series;2020-06-01

2. Detector Control System for the GE1/1 slice test;Journal of Instrumentation;2020-05-28

3. Layout and assembly technique of the GEM chambers for the upgrade of the CMS first muon endcap station;Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment;2019-02

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3