Physics Studies for Assessment of Requirement of Displacement Compensation System for ITER ECE Diagnostic

Author:

Danani S.,Pandya Hitesh Kumar B.,Vaghashiya Pratik,Padasalagi Shrishail,Kumar Ravinder,Rowan W. L.,Ziegel J. P.,Kumar Vinay

Abstract

The Electron Cyclotron Emission (ECE) diagnostic has the key function of measuring the core electron temperature profile and electron temperature fluctuation, from the intensity of electron cyclotron radiation emitted from the plasma along the major radius. The ECE diagnostic consists of three main systems: (1) front-end optics, which collects the radiation from the plasma, (2) transmission lines including polarizer splitter unit, which transports the ordinary and extraordinary ECE emission modes separately from the front-end and distributes it to the instrumentation, and (3) detection and analysis instrumentation which is housed at a distance from the tokamak, in the diagnostics building [1]. With its high electron temperatures and harsh environment, ITER presents various challenges for the diagnostic system. One of the most insidious is the misalignment between the in-vessel front-end optics and the ex-vessel transmission line which is caused by vibration of the vacuum vessel during operational and baking phases. Since the electron temperature is inferred from the intensity of the ECE, transient misalignment may lead to poor accuracy in this critical measurement. These displacements are expected to be ~ 15 mm in vertical (z) and horizontal (x) directions, and ~ 5 mm in the toroidal (y) direction. It is important to minimize the effect of these displacements, so that the system maintains alignment during operation, and reliable temperature information is attained. Our objective is to first study the coupling losses due to imperfect coupling of Gaussian beams owing to port plug displacements. Measurements are done to determine the power loss due to coupling of offset beams experimentally. The measured value for coupling loss is ~2 dB at 120 GHz, which is quite high, and it is therefore concluded that a mechanism is needed to compensate for the displacements.

Publisher

EDP Sciences

Subject

General Medicine

Reference3 articles.

1. Update on the status of the ITER ECE diagnostic design

2. Thermal relative displacements of the ITER Vacuum Vessel Port Flanges & Connecting Ducts (VV PHTS temperature effect) IDM UID L9VRZK

3. Goldsmith P F, Quasioptical Systems: Gaussian Beam Quasioptical Propagation and Applications (IEEE Press Series on RF and Microwave Technology), 1998

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3