Method for assessing the impact of residual roughness after corneal ablation simulated as random and filtered noise in polychromatic vision

Author:

Verma Shwetabh,Hesser Juergen,Arba-Mosquera Samuel

Abstract

Purpose: Despite theoretical models for achieving laser-based ablation smoothness, methods do not yet exist for assessing the impact of residual roughness after corneal ablation, on retinal polychromatic vision. We developed a method and performed an exploratory study to qualitatively and quantitatively analyze the impact of varying degree of corneal roughness simulated through white and filtered noise, on the retinal image. Methods: A preliminary version of the Indiana Retinal Image Simulator (IRIS) [Jaskulski M., Thibos L., Bradley A., Kollbaum P., et al. (2019) IRIS – Indiana Retinal Image Simulator. https://blogs.iu.edu/corl/iris] was used to simulate the polychromatic retinal image. Using patient-specific Zernike coefficients and pupil diameter, the impact of different levels of chromatic aberrations was calculated. Corneal roughness was modeled via both random and filtered noise [(2013) Biomed. Opt. Express 4, 220–229], using distinct pre-calculated higher order Zernike coefficient terms. The outcome measures for the simulation were simulated retinal image, Strehl Ratio and Visual Strehl Ratio computed in frequency domain (VSOTF). The impact of varying degree of roughness (with and without refractive error), spatial frequency of the roughness, and pupil dilation was analyzed on these outcome measures. Standard simulation settings were pupil size = 6 mm, Defocus Z[2, 0] = 2 μm (−1.54D), and Spherical Aberrations Z[4, 0] = 0.15 μm. The signal included the 2–4th Zernike orders, while noise used 7–8th Zernike orders. Noise was scaled to predetermined RMS values. All the terms in 5th and 6th Zernike order were set to 0, to avoid overlapping of signal and noise. Results: In case of a constant roughness term, reducing the pupil size resulted in improved outcome measures and simulated retinal image (Strehl = 0.005 for pupil size = 6 mm to Strehl = 0.06 for pupil size = 3 mm). The calculated image quality metrics deteriorated dramatically with increasing roughness (Strehl = 0. 3 for no noise; Strehl = 0.03 for random noise of 0.25 μm at 6 mm diameter; Strehl = 0.005 for random noise of 0.65 μm at 6 mm diameter). Clear distinction was observed in outcome measures for corneal roughness simulated as random noise compared to filtered noise, further influenced by the spatial frequency of filtered noise. Conclusion: The proposed method enables quantifying the impact of residual roughness in corneal ablation processes at relatively low cost. Since normally laser ablation is an integral process divided on a defined grid, the impact of spatially characterized noise represents a more realistic simulation condition. This method can help comparing different refractive laser platforms in terms of their associated roughness in ablation, indirectly improving the quality of results after Laser vision correction surgery.

Funder

ZIM

Publisher

EDP Sciences

Subject

Atomic and Molecular Physics, and Optics

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3