Analysis of a Dry-type Reactor Fault Based on COMSOL Thermal Field Simulation and High Frequency Pulse Oscillations

Author:

Xin LUO,Shuai-yi WANG,Yao WANG,Yu GU

Abstract

For a single-phase earth fault of 35 kV dry-type reactor, the 5th package area is found with serious turn-to-turn short circuit after it conducts the DC resistance test, turn-to-turn insulation test of high frequency oscillation pulse and rework disassembly. The turn-to-turn short circuit of resistance will lead to wire fusing, which makes the conventional pre-test projects have limitations. With COMSOL finite element thermal field simulation of the fault 35kV dry-type reactor, the temperature distribution result of the reactor indicates that the hottest point is at the 6th package during the reactor operation and the temperature rises 73.75K. In addition, the temperature rises of the 5th, 7th, 14th, 15th package is also higher than other packages, which easily causes device failure due to insulation deterioration. Through the analysis and thermal field simulation of the test for failed reactor, it can provide the reference basis for equipment design, manufacture, daily repair and maintenance.

Publisher

EDP Sciences

Subject

General Medicine

Reference15 articles.

1. Changgen XIA. 35 k V together of dry type hollow shunt reactor failure analysis[J]. Power Capacitor & Reactive Power Compensation, 2009 (5): 43-45.

2. Operation and Maintenance Department of SGCC. The casebook for typical failure on transformers [M]. Beijing, China: China Electric Power Press, 2012: 120-144.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3