Evaluation of silicon and 10% bismuth shield with variable thickness compared with constant thickness on the dose reduction and image quality during chest CT examination

Author:

Abolhadi S.,Parach A.A.,Mehdipour A.,Mehnati P.,Sayadi A.R.

Abstract

One of the best methods to reduce the breast radiation dose in chest CT scan exam is using the bismuth shield. Due to the fact that, in CT scan tests, the breast dose is higher in the central axis of body than other sides, so the bismuth shield with variable thickness (outer half 1 mm thick and inner half 2 mm thick) is designed in this study. The objective of this study is to investigate in effectiveness of silicon and 10% bismuth composite shied with variable thickness on reducing radiation dose and image quality parameters in chest CT scan test compare to 1 mm and 2 mm of fixed thickness shield. Physical chest phantom underwent chest CT scan without or with bismuth shields with thickness of 1 mm, 2 mm, and variable in 90, 120 and 140 kVp in inactive TCM mode. Dosimetry was performed by using TLD, and image quality was evaluated quantitatively (by drawing the ROI in the identical images like image j, calculation of noise, CT number, SNR and CNR) and qualitatively (by two expert radiologists). Designed bismuth shield with unsteady thickness in inner and outer side compare to 1 mm and 2 mm thickness shields is presented in 120 kVp, has a significant difference in the amount of breast dose reduction (19% reduction), as well as in 140 kVp, all these three bismuth shields resulted in a significant dose reduction almost in the same similarity. At 120 kVp, the bismuth shield with variable thickness lead to a significant change in CT numbers in the heart and lungs, but it does not have a remarkable effect on other image quality parameters. The bismuth shield with variable thickness can lead to a better effectiveness in reducing breast dose without any side effect on image quality at 120 kVp, which requires further studies in this field.

Publisher

EDP Sciences

Subject

Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health,Waste Management and Disposal,Safety, Risk, Reliability and Quality,Nuclear Energy and Engineering,Renewable Energy, Sustainability and the Environment

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3