Abstract
This study proposes a quick, easy, and low-cost method that can be used to assess the radiological safety of an irradiation line used for cargo and container inspection facilities. The radiation-emitting equipment used was a Smiths Heimam particle accelerator model HCVP4029 operating at 4.5 MeV. The radiation dose measurements were performed using a personal radiation monitor Ultra Radac mod MRAD 111 (Geiger–Muller). The ambient equivalent dose H*(10) was estimated for two facilities: A (real) (1.12E-03 mSv per scan) and B (fictitious) (3.25E-03 mSv per scan). The dimensionless factor R, which represents a ratio between two specific scanning (Ss) quantities regarding the facilities A and B, is introduced as a reference for assessing the level of radiological safety. This study compares facilities A and B by using a simple alternative safety assessment based on the R factor. The dimensionless R-value appears to be able to facilitate both the personnel’s and the general public’s perception of risk levels, even with no fixed scale.
Subject
Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health,Waste Management and Disposal,Safety, Risk, Reliability and Quality,Nuclear Energy and Engineering,Renewable Energy, Sustainability and the Environment
Cited by
2 articles.
订阅此论文施引文献