Etablissement de niveaux de référence diagnostiques locaux pour les protocoles de tomodensitométrie en radiothérapie du cancer du sein dans un seul centre marocain
-
Published:2023-12-18
Issue:
Volume:
Page:
-
ISSN:0033-8451
-
Container-title:Radioprotection
-
language:
-
Short-container-title:Radioprotection
Author:
Nhila O.,Talbi M.,Youssoufi M.,El Mansouri M.,tahiri Z.,Chakir E.,Azougagh M.
Abstract
The objective of this study was to establish local diagnostic reference levels (LDRLs) for breast cancer computed tomography imaging in radiotherapy (CT-RT) at a single hospital in Morocco. Data were collected from 106 adult breast cancer patients aged between 33 and 78 years during five months. Data were obtained using a Hitachi Supria 16-slice CT simulator at a regional oncology center in Morocco. CT-RT images are intended for 3D conformal radiotherapy treatment planning. Dose length product (DLP) and volumetric computed tomography dose index (CTDIvol) were evaluated by determining the 75th percentile as diagnostic reference levels for CT-RT breast cancer. LDRLs for CT-RT breast cancer have been determined in terms of DLP and CTDIvol, and they were 330.4 mGy.cm and 6.8mGy, respectively. The DRLs were compared with other Europeans study. DRLs for this study were lower than those for the United Kingdom (UK), Croatia and Slovenia. The results of this study can be a reference for the establishment of local and national DRLs in Morocco and the optimization of CT-RT breast cancer procedures.
Subject
Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health,Waste Management and Disposal,Safety, Risk, Reliability and Quality,Nuclear Energy and Engineering,Renewable Energy, Sustainability and the Environment