Development of Electromyography Signal Contraction Detection Using the Double Threshold Method for Controlling Wheelchair

Author:

Yulianto Endro1,Muzakkir Heru Wildan1,Triwiyanto Triwiyanto1ORCID,Nugraha Priyambada Cahya1,Prastawa Moch P.1,Lamidi 1

Affiliation:

1. Poltekkes Kemenkes Surabaya

Abstract

The consequence of spinal cord injury (SCI) is the malfunction of some parts of the body. This observation especially applies to trauma at the cervical level, because both patients' hands and legs are no longer functioning. The purpose of this study was to determine the mechanism of the comparator treshold system in electric wheelchairs for patients with paralysis. The research contribution is to get a treshold mechanism that can make a wheelchair run smoothly without being affected by the strength of the user's unstable muscle contractions. To set the muscle reference value, connect the transmitter to Android using USB Cable. On Android there are 2 settings modes, namely manual and auto settings. The method used in auto mode is the transmitter will take 100 contraction and 100 relaxation data and multiplied by certain constants to get the upper and lower threshold values. In setting the threshold manually, the value is set based on the strength of the patient's contractions that are displayed on Android manually. Where in the threshold setting manually obtained response 93.3% of forward movement, 100% of turn left movement, 100% of turn right movement and 93.3% of backward movement. Meanwhile, the threshold setting automatically gets 80% response for forward movements, 93.3% for turn left movements, 86.6% for turn right movements and 93.3% for backward movements. The results of the tapping into 4 parts of the muscle can be implemented to detect muscle contractions so that the wheelchair can move according to orders. The problem obtained in this study is that there are many tapping points on the face so that it interferes with the comfort and time of installing electrodes on the face, also the patient's muscle reference setting system on Android still needs the help of others. In the future, it is expected to reduce tapping points and improve the efficiency of muscle threshold settings.

Publisher

Trans Tech Publications, Ltd.

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3