Biomechanical Effects of Titanium Alloy Based Single versus Dual Cage Fusion Devices

Author:

Singh Nitesh Kumar1,Verma Rati1,Kumar Pradeep2,Singh Nishant Kumar1ORCID

Affiliation:

1. National Institute of Technology

2. Alkermes Inc.

Abstract

Degenerative disc disease is an increasing problematic complication following lumbar fusion surgeries. Posterior lumbar interbody fusion (PLIF) is a well-established surgical method for spine stability following intervertebral disc removal. The position and number of titanium cages in PLIF are remain contingent on individual surgeon experience. Thus, a systemic investigation of the efficacy of titanium single mega cage versus two cages in treating degenerative lumbar spinal diseases is imperative. A biomechanical study was aimed to compare the stability achieved in PLIF through interbody reconstruction using a single mega cage (32 mm) Vs. a dual cage (22 mm). Normal intact finite element model of L3–L4 was developed based on computed tomography images from a healthy 27-year-old male volunteer. The study tested the intact model (Model A) and its surgically operated counterparts using four PLIF implantation methods: single transverse cage (Model B), single transverse cage with bone graft (Model C), dual transverse cage (Model D), and dual transverse cage with bone graft (Model E). Combined loads simulating physiological motions—flexion, extension, axial rotation, and lateral bending —were applied across all loading directions. The assessment includes all model range of motion (ROM), micromotion between the cage and endplate, and stress on the cage and internal fixation system (screw and rod). The ROM between Models B, C, D and E were consistently reduced by over 71% compared to intact Model A under all motion scenarios. Model D exhibited the highest peak stress of 115 MPa on the cage during flexion, surpassing Model C and E (Flexion) by fourfold. Model E demonstrated the lowest cage stress (20 MPa) during extension, outperforming the other models. Notably, Model E exhibited minimal endplate stress (2 MPa), cage stress (21 MPa), micromotion (13 µm) during extension, and screw-rod stress (56 MPa) during flexion, making it superior to other implantation methods. In the context of PLIF, Model E showed enhanced biomechanical stability, reducing ROM, stress on the endplates, cage, screw-rod system and micromotion. Alternatively, Model C may be a viable alternative in standard PLIF, especially in cases with limited intervertebral space, providing efficient clinical outcomes with shorter operative times and reduced costs and ease of implantation. Also, this computational study provides valuable understandings into optimizing cage implantation strategies for improved outcomes during PLIF.

Publisher

Trans Tech Publications, Ltd.

Reference45 articles.

1. The Treatment of Ruptured Lumbar Intervertebral Discs by Vertebral Body Fusion;Cloward;Journal of Neurosurgery

2. 4 Lesions of the Intervertebral Disks and Their Treatment by Interbody Fusion Methods The Painful Disk;CLOWARD;Clinical Orthopaedics and Related Research

3. Lumbar interbody fusion: recent advances in surgical techniques and bone healing strategies;Meng;European Spine Journal,2020

4. W.F. Lestini, J.S. Fulghum, L.A. Whitehurst, Lumbar spinal fusion: advantages of posterior lumbar interbody fusion, Surgical technology international. 3 (1994) 577-590.

5. Comparison of low back fusion techniques: transforaminal lumbar interbody fusion (TLIF) or posterior lumbar interbody fusion (PLIF) approaches;Cole;Current Reviews in Musculoskeletal Medicine,2009

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3