Cementing Line Configuration of Bioactive Engineered Zirconia Implants (In Vivo Histological Study)

Author:

Ahmed Dawlat Mostafa1,Omar Samia Soliman1

Affiliation:

1. Alexandria University

Abstract

Background: Osseointegration of dental implant is a challenging issue for those who need to restore a missing tooth, a matter that necessitates wide range of research on different implant manufacturing, modification and bioactive coating materials.Aim of the study: Investigation of cementing line configuration around osseointegrated engineered nano-porous zirconia implants coated with bioactive autologous HA, platelet rich plasma (PRP) and bovine HA (Bio-oss) coatings in rabbit model.Materials and methods: Zirconia implants (cylinders 3.7 mm x 8 mm) were milled and sintered according to manufacturer recommendations. Then all specimens were treated with selective infiltration etching (SIE) to produce a nano-porous surface. Implants were surgically placed bilaterally in the femur distal heads of 20 male line V Spain white rabbits. Implants were divided equally into 4 groups (n=10): group (A) control (non-coated), group (B) autologous HA coated, group (C) PRP coated and group (D) Bio-Oss coated implants. Specimens were characterized with x-ray diffraction (XRD) analysis and mercury porosimetery. Histological examination was performed after six weeks of peri-implant healing period.Results: XRD patterns revealed the detection of hexagonal HA and (Y-TZP) tetragonal crystal phases for the HA coated surfaces. Mercury porosimetery revealed a significant reduction in total porosity percent after application of bioactive coating materials. The histological picture of osseiointegration and cementing line continuity in association with both of autologous HA and PRP were outstanding and satisfactory followed by that of Bio-Oss and all coated implants showed a noticeable difference from that of the control specimens that were surrounded by unsupported cementing line adjacent to newly formed bone with low density.Conclusions: Engineering of zirconia implant surface with bioactive coatings either HA or PRP to enhance its biological activity could be considered as reliable method to provide satisfactory osseiointegration.

Publisher

Trans Tech Publications, Ltd.

Subject

Mechanical Engineering,Mechanics of Materials,General Materials Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3