Affiliation:
1. Politecnico di Milano
2. University Paris-Est, CSTB
Abstract
The present work deals with numerical simulations concerning the international benchmark “Vulcain tests on 3 Walls” regarding fire tests conducted in CSTB in Paris, France. To this aim, sequentially-coupled thermo-mechanical analyses have been performed on three reinforced concrete walls, characterized by different load levels and boundary conditions. The numerical results show that the imposed compressive load and boundary conditions significantly influence the magnitude of the displacements. In the case of simply supported walls, the wall with the lower load level exhibited a gradual and monotonic increase of the displacements at mid-height (both in the tests and in the numerical analyses), while the wall with the higher load level exhibited a displacement reversal due to second-order effects after approximately 60 minutes of fire exposure. This reversal, which was obtained in the analyses, was not observed in the test. Load bearing capacity of all the three specimen walls was maintained in such a way that the collapse did not take place during two hours of fire exposure.
Publisher
Trans Tech Publications, Ltd.
Subject
Mechanical Engineering,Mechanics of Materials,General Materials Science
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献