Affiliation:
1. CEITEC – Central European Institute of Technology
Abstract
The paper focuses on the metallographic analysis of the damaged inner shaft of a centrifugal pump with a magnetic clutch. This pump was used for the pumping of viscous suspensions. The damaged part of the centrifugal pump was made of stainless steel and transmitted power from the magnetic clutch to the impeller of the pump. The pump was overhauled by the Manufacturer after ten years of routine work. Slightly worn parts of the pump, including the inner stainless steel shaft, were replaced by the Manufacturer according to the preserved documentation. The overhauled pump failed after two days of running in the original conditions. The problematic is solved by an analysis of three used inner shafts with the aid of a metallographic analysis of the microstructure of the material, using light microscopy and scanning electron microscopy, and an EDS microanalysis of the chemical composition and hardness measurements.
Publisher
Trans Tech Publications, Ltd.
Subject
Condensed Matter Physics,General Materials Science,Radiation