Abstract
The effect of brazing temperature on the properties of brazed joints between WC-Co hard
alloy and SAE1045 carbon steel using Cu and ASTM C52100 bronze metal as insert fillers were
investigated. A vacuum brazing furnace was employed to conduct the experiment with different sets
of operational parameters (brazing temperature, bonding time and filler) were used. The
experimental result shows that Fe-Co-Cu alloy layer was formed at the WC-Co/Cu filler interface.
With increased brazing temperature and bonding time, the thickness of the Fe-Co-Cu layer
increases. From the shear test, the maximum shear strength is 320±10 MPa for the joint brazed at
1140°C for 15 min using Cu filler. The shear strength of WC-Co/C52100/SAE1045 brazed joints
was better than WC-Co/Cu/SAE1045 brazed joints. The increase of bonding time of
WC-Co/C52100/SAE1045 joints improved the shear strength slightly.
Publisher
Trans Tech Publications, Ltd.
Cited by
18 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献