Abstract
In this research permendur (49Fe-49Co-2V) and nickel were used to make a novel
bimetal actuator. The actuator consists of a main body and core with energizing coil. The main body
of actuator is made of annealed permendur with two magnetostrictive bimetal arms. The
magnetostrictive bimetal technique is used to enhance the small displacement of permendur. Static
and dynamic behaviors of the actuator are investigated at both, room temperature (RT) and 77 K.
The actuator magnified the small displacement of permendur strip (1.8 µm) and large displacement
of 9 and 5 µm are achieved at RT and 77 K, respectively when the coil was energized by ± 5 A
current. Additionally, it is found that resonance frequency of actuator is 1240 Hz at 77 K and 1125
Hz at RT. Since the stiffness of actuator increases at 77 K, the displacement of actuator is reduced
33-50% when the coil is energized with different amplitudes at cryogenic environments.
Publisher
Trans Tech Publications, Ltd.
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献