Abstract
Recently, more attention has been devoted to porous implants to avoid stress-shielding effects and facilitate anchor effects. In addition, our previous research revealed that uniaxially aligned pores promoted early recovery of bone tissue with high bone quality similar to that of intact bone. In this study, Ti-based implant materials with uniaxially aligned pores were fabricated using the electron beam melting (EBM) method with 2 types of grid spacing, 0.5 and 1.0 mm. Although grid spacing was varied, the constituent phase and microstructure of the products were homogenous regardless of the grid spacing. Uniaxially aligned pores were created when the grid spacing was 1.0 mm, whereas almost solid structures with random pores were formed when the grid spacing was 0.5 mm. Young’s modulus of the products with the grid spacing of 1.0 mm was 34 GPa; this value is close to that of the bone. It is concluded that the porous material with aligned pores is suitable as a bone implant to reduce stress-shielding effects and to induce bone regeneration with good bone quality.
Publisher
Trans Tech Publications, Ltd.
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献