Abstract
Two-phase closed thermosyphon has been widely used in many heat transfer devices due to its high thermal conductivity, low cost and sample structure. During its starting and operation, there have some unstable oscillation, including dry oscillation, geyser boiling and carrying oscillation. An experimental investigation of unstable oscillation of two-phase closed thermosyphon was presented in the present paper. The experimental results showed that under the same starting power, geyser boiling is easy to achieve stability with the cooling power increasing, and under the same cooling power condition, geyser boiling could be significantly affected by the starting power. At the situation of high heating power, carrying oscillation happened easily, which caused great temperature fluctuation and disastrous effects on the heat pipe.
Publisher
Trans Tech Publications, Ltd.
Reference8 articles.
1. Ma Tongze, Hou Zengqi, Wu Wenxian. Heat Pipe[M]. Beijing: Science and Technology Press (1983).
2. Zhuang Jun, Zhang Hong. Heat Pipe Technology and Engineering Application[M]. Beijing: Chemical Industry Press (2000).
3. Faghri A. Heat Pipe science and technology [M]. Washington DC: Taylor & Francis (1995).
4. Masataka Mochizuki, Thang Nguyen, Koichi Mashiko, et al. Practical application of heat pipe and vapor chamber for cooling high performance personal computer[A]. In: 13th International Heat Pipe Conference [C], Shanghai (2004).
5. Cotter T P. Principles and prospects for micro heat pipes. In: Fifth international heat pipe conference[C], Tsukuba, Japan (1984).
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献