Abstract
Since 2001, ACI 319 adopted the CCD equation for the concrete breakout capacity and a modified equation was recently included in 2011. In this study a new equation to predict the concrete breakout capacity of CIP anchor under shear loading was proposed. The equation was derived from multi-variable regression on the test results conducted by the authors and other researchers. It was found that the proposed equation could consistently predict the shear breakout capacity from small to large diameter anchors and edge distances.
Publisher
Trans Tech Publications, Ltd.
Reference7 articles.
1. ACI Committee 349: Code Requirements for Nuclear safety Related Concrete Structures (ACI 349-90); Appendix B Steel Embedments, American Concrete Institute (1990), pp.80-86.
2. W. Fuchs, R. Eligehausen and J.E. Breen: Concrete Capacity Design(CCD) Approach for Fastenings to Concrete, ACI Structural Journal (1995), Vol. 92, No. 6, pp.794-802.
3. ACI Committee 318-02: Building Code Requirements for Structural Concrete(ACI 318-02)and Commentary; Appendix D Anchoring to Concrete, American Concrete Institute (2002).
4. N.H. Lee, K.R. Park and Y.P. Suh: Shear Behavior of headed Anchors with Large Diameters and Deep Embedments, ACI Structural Journal, Vol. 107, No. 2, (2010), pp.146-156.
5. R.E. Klingner, H. Muratli and M. Shirvani: A Technical Basis for Revision to Anchorage Criteria, NUREG CR-5563, U.S. Nuclear Regulatory Commission (1999).