Abstract
In the current study, the bulk etch rate VB of solid state nuclear track detectors SSNTDs CR-39 have been examined at different concentrations of NaOH solution ranged from 4N to 8N and different temperatures of NaOH solution (50, 60, 70, 80 °C) for various time intervals of etching (1-10 h); this is done by determination of mass variation via etching time. The results indicate that the bulk etch rate VB increases with the increase of etchant solution concentration and the temperature of solution. This can be attributed to the increase the thickness of the removed layers h of the detector.
Publisher
Trans Tech Publications, Ltd.
Reference9 articles.
1. A. A. Al-Hamzawi, M. S. Jaafar, N. F. Tawfiq, Uranium concentration in blood samples of Southern Iraqi leukemia patients using CR-39 track detector, Journal of Radioanalytical and Nuclear Chemistry 299 (2014) 1267-1272.
2. A. A. AL-Hamzawi, M. S. Jaafar, N. F. Tawfiq, N. F. Salih, Uranium concentration in human blood using fission track etch technique, Journal of Natural Sciences Research. 13 (2013) 176-181.
3. H.A. Khan, I.E. Qureshi, SSNTD Applications in science and technology, Radiat. Meas. 31 (1991) 25–45.
4. T. M. Hegazy, M. Y. Shoeib, G. M. Hassan, The effect of different gamma doses on some properties of a CR-39 detector, Radiation Protection Dosimetry. 155 (2013) 389–393.
5. S .A. Durrani, Handbook of radioactivity analysis, New York, 2003, pp.179-192.