Affiliation:
1. University of the Philippines
Abstract
Dendrites were observed in the failure of semiconductor sensor devices. EDX analysis showed that the dendrites grown from bare sensor dice consisted of tin metal. The tin dendrites exhibited massive and dense branches. Dendrites grown from mechanically decapped parts consisted of silver. The silver dendrites exhibited delicate, lace-like structure. Binary and grey scale images of dendrites were analyzed for fractal dimension number and branch density. The tin dendrites had a higher, statistically significant branch density number than silver, due to tin’s more intricate branching pattern. Fractal numbers can be used to differentiate between tin and silver dendrites, even in the absence of EDX analysis equipment.
Publisher
Trans Tech Publications, Ltd.
Subject
Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics,General Materials Science
Reference8 articles.
1. L. S. Belandres, J. B. Junio, J. Breitsprecher, Electrochemical Migration of Silver in Diode Temperature Sensors, 24th ASEMEP National Technical Symposium, Manila, Philippines (June 2014).
2. M. G. Mena and M. S. Mena, Electrochemical Migration of Silver in Electronics Application, Annual Conference Canadian Institute of Metallurgists, Ontario, Canada (October 2012).
3. H. S. Villanueva, M. G. Mena, P. C. Naval, An Automatic Visual System to Identify and Estimate Ionic Contamination in Printed Circuit Boards using Electrochemical Migration Patterns, Proceedings, 2014 IEEE 16th Electronic Packaging Technology Conference, December 3 - 5, Singapore (Dec. 2014).
4. S. Yang, J. Wu, A. Christou, Initial Stage of Silver Electrochemical Migration Degradation, Microelectronics Reliability, 46 pp.1915-1921 (2006).
5. M. Zamanzadeh, S. L. Meilink, G. W. Warren, P., Wynblatt, B. Yan, Electrochemical Examination of Dendritic Growth on Electronic Devices HCL Electrolytes, Corrosion, Vol. 46, No. 8, pp.665-671 (Aug. 1990).
Cited by
2 articles.
订阅此论文施引文献