TWIP steel has the characteristics of high elongation and high tensile strength at room temperature, and therefore it is widely used in the automobile manufacturing industry. Since the grain size has a very important influence on its mechanical properties and corrosion resistance it is significant to study the average grain size of TWIP steel. In this experiment, the specimens were heated to 700~1000°C and preserved for one hour, and the recrystallized structures with different average grain sizes were obtained. All the samples were tested by laser ultrasonic experimental platform and the standard sample was selected. Then the attenuation coefficients of remaining samples were compared with the standard samples by conventional methods. The results showed that the larger the difference between the average grain size of the test sample and the standard sample is, the greater the error of the test will be. The new evaluation model was established by the improved method, and the prediction error was reduced to 5.44~11.61%, which proved the effectiveness of the new method. In addition, laser ultrasonic testing has the advantages of high efficiency and no damage compared with traditional methods.
Publisher
Trans Tech Publications, Ltd.
Subject
Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics,General Materials Science
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献