Affiliation:
1. Tomas Bata University in Zlin
Abstract
Patients and surgeons with tibia fracture using external fixator are worried about a higher weight of metal fixator´s construction and therefore also poor manipulation ability with this tool [1]. During the last few years the bone tissue engineering has improved significantly and along with that also material development has increased [2,3]. Therefore patients requirements can be achieved by optimizing the material composition of this product. The main objective of this research is a weight reduction by material and design changes of the external fixator. Another aim is the evaluation of the final model. The model of innovative fixator was created and also computed in software CATIA V5-6 using finite element method simulation. Appropriate forces were applied and the simulation was performed. Results of FEM simulation indicate that the final weight of complete product declined significantly after application of carbon-fiber composite. Test results also suggest that the rigidity and the stability of complete fixator are safe. Hence this research describes that application of carbon fiber composite into the external fixator design is an important improvement of the external fixator.
Publisher
Trans Tech Publications, Ltd.
Subject
Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics,General Materials Science
Reference17 articles.
1. J. Gessman, B. Jettkant, T.A. Schildhauer, D. Seybold, Mechanical stress on tensioned wires at direct and indirect loading: A biomechanical study on the Ilizarov external fixator, Injury, Volume 42, Issue 10 (2011) 1107-1111.
2. S. Zahaf, S. Kebdani, M. Dahmane, Z. Azari, The Biomechanical comparison between two models of the lumbar intersomitic fusion cage analyzed by the finite element method, Sci., Issue 10 (2017) 40 - 58.
3. C. Migliaresi, F. Nicoli, S. Rossi, A. Pegoretti, Novel use of carbon composites for the fabrication of external fixators, Composites science and technology, Sci., Vol.: 64, Issue 6 (2004) 873 - 883.
4. D. Kytyr, T. Doktor, O. Jirousek, T. Fila, P. Koudelka, P. Zlámal, Deformation behavior of a natural shaped bone scaffold. , Mater. Tehnol., 50 (2016) 3, doi: 10. 17222/mit. 2014. 190.
5. D. P. Jevremovic, T. M. Puskar, I. Budak, D. Vukelic, V. Kojic, D. Eggbeer, R. J. Williams, An RE/RM approach to the design and manufacture of removable partial dentures with a biocompatibility analysis of the F75 Co-Cr SLM alloy., Mater. Tehnol., 46 (2012).
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献