Abstract
A fitting procedure of the Curie-Weiss law, eliminating the temperature independent contribution (0) from the experimental susceptibility data, was used for determination of the magnetic parameters, i.e. a Curie constant, a Curie-Weiss temperature and an effective magnetic moment, because the theoretical considerations showed that the Curie-Weiss law is invalid for 0 0, even small. This method revealed for the HgCo(NCS)4 paramagnet, commonly accepted as a magnetic susceptibility standard, 0 = 2.43710-6 cm3/g, while for the ZnCr2Se4 antiferromagnet, known as a matrix of various diluted systems, – 0 = -2.56610-6 cm3/g, for comparison.
Publisher
Trans Tech Publications, Ltd.
Subject
Condensed Matter Physics,General Materials Science,Atomic and Molecular Physics, and Optics
Reference14 articles.
1. A.H. Morrish: Physical Principles of Magnetism (John Wiley & Sons, Inc., New York, 1965).
2. B.N. Figgis and R. S. Nyholm: J. Chem. Soc. Vol. 11 (1958), p.4190.
3. S.A. Kuzaiev, P.W. Usatchiev and W.M. Ubin: Fiz. Tver. Tela Vol. 13 (1971), p.2829.
4. D.B. Brown, V.H. Crawford, J.W. Hall and W.E. Hatfield: J. Phys. Chem. Vol. 81 (1977), p.1303.
5. D. Nelson and W. ter Haar: Inorg. Chem. Vol. 32 (1993), p.182.
Cited by
33 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献