Abstract
Lumped and distributed dynamic/static models of constant temperature hot-wire probe are established according to heat balance principle. Dynamic and static characteristics of hot-wire probe are analyzed in terms of hot-wire probe sizes, control circuit parameters and flow velocity.Simulation results show that reliability and stability of the hot-wire probe depend on bias voltage.The dynamic and static characteristics of hot-wire probe refly on the ratio of length to diameter ratio crucially.Once the ratio exceeds 300, heat conduction terminal loss can be ignored. When over-heating ratio of hot- wire or flow velocity increases, heat conduction terminal loss can be omitted as well .Besides frequency response of hot-wire probe can be improved simultaneously.The above conclusions can provide guidance in the improved design for hot-wire probe and its control-circuits.
Publisher
Trans Tech Publications, Ltd.
Reference12 articles.
1. Spina E F, Mcginley C B. Experiments in Fluids , 1994, 17(6): 365-374.
2. Jinglei Xu, Chao Li, Jiang Sha et al. Journal of Aerospace Power, 2007, 12 (11) : 1846-1851.
3. King L v. Phil. Trans. Roy. Soc, 1914: 373-432.
4. Perry A. E, Morrison G.L.J. Fluid Mech, 1971, 47(3): 577-599.
5. Perry A.E. Hot_wire anemometry[M]. New York: Oxford University Press, (1982).